Changelog for SPS TestManager v2.17.1 from 20.05.2025

Automotive

  • BMW GS 95003-2
    • 5.2.1.4 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • 5.2.1.7.1 Brief off / on for bus nodes: Display texts in the information screen on used devices revised.
    • 5.2.1.9 Voltage impulse due to switch-off of loads: Display texts in the information screen on used devices revised.
    • 5.3.5 Short-circuit strength: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
  • BMW GS 95024-2-2
    • E-10 Short interruptions: Display texts in the information screen on used devices revised.
    • E-13 Pin interruption: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • E-16 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-17 Short circuit in signal circuit and load circuits: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-21 Backfeeds: Display texts in the information screen on used devices revised. Block diagram updated
    • E-41 Brief off on for bus nodes: Display texts in the information screen on used devices revised.
    • E-42a Negative voltage impulse on switched supply voltages: Display texts in the information screen on used devices revised.
  • BMW GS 95026
    • E48-05 Superimposed AC voltage: Test integrated
    • E48-09 Short interruptions: Display texts in the information screen on used devices revised.
    • E48-11 Mass loss: Error at test start fixed. Display texts in the information screen on used devices revised.
    • E48-12 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E48-21 Short circuit in signal circuit and load circuits: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
  • FCA CS.00054
    • 5.5.1 Immunity to Short Circuits in the Supply Voltage Input and Load Outputs Lines: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • 5.3.2 Supply Voltage Drop Out: Display texts in the information screen on used devices revised.
    • 5.3.3 Power Supply Disconnection: Display texts in the information screen on used devices revised. Block diagram updated.
    • 5.3.5 Supply Voltage Dips: Button release corrected
  • Fiat 9.90111-01
    • 4.4.1 Immunity to Short Circuits in the Supply Voltage Input and Load Outputs Lines: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • 4.2.2 Supply Voltage Drop Out: Display texts in the information screen on used devices revised.
    • 4.2.3 Power Supply Disconnection: Display texts in the information screen on used devices revised. Block diagram updated.
    • 4.2.5 Supply Voltage Dips: Button release corrected
    • 6.4.2 Transient Immunity of I/O or Sensor Lines (CCC): Default values corrected
  • Ford FMC1278
    • -CI 231: Pulse image revised
  • ISO 16750-2
    • 4.9 Open circuit test: Test implemented.
    • 4.10 Short circuit/overload protection: Test implemented
    • 4.6.1.2 Micro interruption in supply voltage: Display texts in the information screen on used devices revised. Block diagram updated
  • ISO 21848
    • Test-12: Ground loss: Revised device synchronization
    • Test-15: Short circuit in signal line and load circuit: Test implemented
  • ISO 21780
    • Test-11: Discontinuities in supply voltage: Display texts in the information screen on used devices revised.
    • Test-12: Ground loss: Display texts in the information screen on used devices revised. Block diagram updated
  • Jaguar JLR-EMC-CS
    • CI 230: Spelling error fixed
    • CI 235 Waveform A: Spelling error fixed
    • CI 265 Waveform B: Spelling error fixed
    • CI 265 Waveform C: Error in the sequence fixed
  • LV 124
    • E-10 Short interruptions: Display texts in the information screen on used devices revised.
    • E-13 Pin interruptions: Error at test start fixed. Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • E-17 Short circuit in signal circuit and load circuits: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-16 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-21 Backfeeds: Display texts in the information screen on used devices revised. Block diagram updated
  • LV 148
    • E48-09 Brief interruptions: Display texts in the information screen on used devices revised.
    • E48-11 Mass loss: Error at test start fixed. Display texts in the information screen on used devices revised.
  • MBN 10567
    • 7.11 Short interruptions test: Display texts in the information screen on used devices revised.
    • 7.12 Pin interruption test: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • 7.15 Ground offset test: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • 7.17 Feedback test: Display texts in the information screen on used devices revised. Block diagram updated
  • MBN LV 124-1
    • E-10 Short interruptions: Display texts in the information screen on used devices revised.
    • E-13 Pin interruption: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • E-17 Short circuit in signal circuit and load circuits: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-16 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-21 Backfeeds: Display texts in the information screen on used devices revised. Block diagram updated
  • Mitsubishi ES-X82114
    • 9.2 Transient Disturbances Conducted along I/O or Sensor Lines: Default values corrected
    • 9.5 Ground reference offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
  • Nissan 28401NDS02
    • EQ/IC 02: Resistance to pulses 3a and 3b: Error during pulse call fixed
    • EQ/IC 04: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • EQ/TE 0504: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
  • PSA B21 7110
    • EQ_IC_04: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • EQ/TE 0504: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
  • Renault 36-00-808
    • EQ/IC 02: Resistance to pulses 3a and 3b: Error during pulse call fixed
    • EQ_IC_04: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • EQ/TE 0504: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
  • SAE j1113-11
    • Pulse 1b Heavy-Duty Trucks: Default values corrected
  • VDA 320
    • E48-09 Brief interruptions: Display texts in the information screen on used devices revised.
    • E48-11 Mass loss: Error at test start fixed. Display texts in the information screen on used devices revised.
  • Volvo 31850329
    • 4.6.1 Momentary drop in supply voltage: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • 4.10. Short circuit protection: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
  • VW 80000
    • E-10 Short interruptions: Display texts in the information screen on used devices revised.
    • E-13 Pin interruption: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated
    • E-17 Short circuit in signal circuit and load circuits: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-16 Ground offset: Manual pulse control revised. Display texts in the information screen on used devices revised. Block diagram updated.
    • E-21 Backfeeds: Display texts in the information screen on used devices revised. Block diagram updated.
  • VW 82148
    • E48-05 Superimposed AC voltage: Error during pulse call fixed
    • E48-11 Mass loss: Error at test start fixed. Display texts in the information screen on used devices revised.

EMC

  • IEC 61000-3-2
    • Recalculation of impedances optimized for frequency changes
  • IEC 61000-3-3
    • Recalculation of impedances optimized for frequency changes
  • IEC 61000-3-11
    • Recalculation of impedances optimized for frequency changes
  • IEC 61000-3-12
    • Recalculation of impedances optimized for frequency changes
  • IEC 61000-4-11
    • The tests are now aborted correctly